# Council Decision of 13 November 2012 on the signing and conclusion of the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment (Text with EEA relevance) (2013/107/EU), Division (i): Procedure for Printers, Digital Duplicators and MFDs with Print Capability, and Fax Machines


Table 6
TEC Test Procedure — Printers, Digital Duplicators and MFDs with Print Capability, and Fax Machines
Step
Initial State
Action
Record (at end of step)
Possible States Measured
1
Off
Plug the unit into meter. Zero the meter; wait test period (five minutes or more).
Off energy
Off
Testing Interval time
2
Off
Turn on unit. Wait until unit indicates it is in Ready mode.
—
—
3
Ready
Print a job of at least one output image but no more than a single job per Job Table.
Record time to first sheet exiting unit. Wait until the meter shows that the unit has entered its final Sleep mode.
Active0 time
—
4
Sleep
Zero meter; wait one hour.
Sleep energy
Sleep
5
Sleep
Zero meter and timer. Print one job per Job Table. Record time to first sheet exiting unit. Wait until timer shows that 15 minutes have elapsed.
Job1 energy
Recovery, Active, Ready, Sleep
Active1 time
6
Ready
Repeat Step 5.
Job2 energy
Same as above
Active2 time
7
Ready
Repeat Step 5 (without Active time measurement).
Job3 energy
Same as above
8
Ready
Repeat Step 5 (without Active time measurement).
Job4 energy
Same as above
9
Ready
Zero meter and timer. Wait until meter and/or unit shows that unit has entered its final Sleep mode.
Final time
Ready, Sleep
Final energy
—
Each image is to be sent separately; they may all be part of the same document, but should not be specified in the document as multiple copies of a single original image (unless the product is a digital duplicator, as specified in section D.2(b)).
For fax machines that only use one image per job, the page is to be fed into the unit's document feeder for convenience copying, and may be placed in the document feeder before the test begins. The unit need not be connected to a telephone line unless the telephone line is necessary for performing the test. For example, if the fax machine lacks convenience copying capability, then the job performed in Step 2 should be sent via phone line. On fax machines without a document feeder, the page should be placed on the platen.

---